manpagez: man pages & more
man Smokeping_probes_FPing(3)
Home | html | info | man
Smokeping_probes_FPing(3)          SmokePing         Smokeping_probes_FPing(3)




NAME

       Smokeping::probes::FPing - FPing Probe for SmokePing


SYNOPSIS

        *** Probes ***

        +FPing

        binary = /opt/local/bin/fping # mandatory
        blazemode = true
        hostinterval = 1.5
        interface = eth0
        mininterval = 0.001
        offset = 50%
        packetsize = 5000
        pings = 20
        protocol = 4
        sourceaddress = 192.168.0.1
        step = 300
        timeout = 1.5
        tos = 0x20
        usestdout = true

        # The following variables can be overridden in each target section
        /^influx_.+/ = influx_location = In the basement

        # [...]

        *** Targets ***

        probe = FPing # if this should be the default probe

        # [...]

        + mytarget
        # probe = FPing # if the default probe is something else
        host = my.host
        /^influx_.+/ = influx_location = In the basement


DESCRIPTION

       Integrates FPing as a probe into smokeping. The variable binary must
       point to your copy of the FPing program.  If it is not installed on
       your system yet, you can get a slightly enhanced version from "pub" in
       www.smokeping.org.

       The (optional) packetsize option lets you configure the packetsize for
       the pings sent.

       Since version 3.3 fping sends its statistics to stdout. Set usestdout
       to 'true' so make smokeping read stdout instead of stderr.

       In blazemode, FPing sends one more ping than requested, and discards
       the first RTT value returned as it's likely to be an outlier.

       The FPing manpage has the following to say on this topic:

       Number of bytes of ping data to send.  The minimum size (normally 12)
       allows room for the data that fping needs to do its work (sequence
       number, timestamp).  The reported received data size includes the IP
       header (normally 20 bytes) and ICMP header (8 bytes), so the minimum
       total size is 40 bytes.  Default is 56, as in ping. Maximum is the
       theoretical maximum IP datagram size (64K), though most systems limit
       this to a smaller, system-dependent number.


VARIABLES

       Supported probe-specific variables:

       binary
           The location of your fping binary.

           Example value: /opt/local/bin/fping

           This setting is mandatory.

       blazemode
           Send an extra ping and then discard the first answer since the
           first is bound to be an outlier.

           Example value: true

       hostinterval
           The fping "-p" parameter, but in (possibly fractional) seconds
           rather than milliseconds, for consistency with other Smokeping
           probes. From fping(1):

           This parameter sets the time that fping  waits between successive
           packets to an individual target.

           Example value: 1.5

       interface
           The name of the network interface to perform the ping on.

           Example value: eth0

       mininterval
           The fping "-i" parameter, but in (probably fractional) seconds
           rather than milliseconds, for consistency with other Smokeping
           probes. From fping(1):

           The minimum amount of time between sending a ping packet to any
           target.

           Example value: 0.001

           Default value: 0.01

       offset
           If you run many probes concurrently you may want to prevent them
           from hitting your network all at the same time. Using the probe-
           specific offset parameter you can change the point in time when
           each probe will be run. Offset is specified in % of total interval,
           or alternatively as 'random', and the offset from the 'General'
           section is used if nothing is specified here. Note that this does
           NOT influence the rrds itself, it is just a matter of when data
           acquisition is initiated.  (This variable is only applicable if the
           variable 'concurrentprobes' is set in the 'General' section.)

           Example value: 50%

       packetsize
           The ping packet size (in the range of 12-64000 bytes).

           Example value: 5000

       pings
           How many pings should be sent to each target, if different from the
           global value specified in the Database section. Note that the
           number of pings in the RRD files is fixed when they are originally
           generated, and if you change this parameter afterwards, you'll have
           to delete the old RRD files or somehow convert them.

           Example value: 20

       protocol
           Choose if the ping should use IPv4 or IPv6.

           Example value: 4

       sourceaddress
           The fping "-S" parameter . From fping(1):

           Set source address.

           Example value: 192.168.0.1

       step
           Duration of the base interval that this probe should use, if
           different from the one specified in the 'Database' section. Note
           that the step in the RRD files is fixed when they are originally
           generated, and if you change the step parameter afterwards, you'll
           have to delete the old RRD files or somehow convert them. (This
           variable is only applicable if the variable 'concurrentprobes' is
           set in the 'General' section.)

           Example value: 300

       timeout
           The fping "-t" parameter, but in (possibly fractional) seconds
           rather than milliseconds, for consistency with other Smokeping
           probes. Note that as Smokeping uses the fping 'counting' mode (-C),
           this apparently only affects the last ping.

           Example value: 1.5

       tos Set the type of service (TOS) of outgoing ICMP packets.  You need
           at laeast fping-2.4b2_to3-ipv6 for this to work. Find a copy on
           www.smokeping.org/pub.

           Example value: 0x20

       usestdout
           Listen for FPing output on stdout instead of stderr ... (version
           3.3+ sends its statistics on stdout).

           Example value: true


AUTHORS

       Tobias Oetiker <tobi@oetiker.ch>



2.8.0                             2021-08-11         Smokeping_probes_FPing(3)

smokeping 2.8.0 - Generated Thu Aug 12 08:55:51 CDT 2021