manpagez: man pages & more
man sane-coolscan(5)
Home | html | info | man
sane-coolscan(5)          SANE Scanner Access Now Easy          sane-coolscan(5)






NAME

       sane-coolscan - SANE backend for Nikon film-scanners



ABOUT THIS FILE

       This file is a short description of the coolscan backend for SANE.



DESCRIPTION

       The sane-coolscan library implements a SANE backend that provides the
       interface to the following Nikon Coolscan Film scanners: Nikon LS20,
       LS30, LS1000, LS2000.

       Even though the backend has worked for a number of people, there are
       still some problems, especially in combination with some SCSI
       card/drivers (AHA-1505/aha152x.o) and the autofocus command.  You should
       consider this backend 'alpha' and be careful when using it the first
       time.



CONFIGURATION

       The configuration file for this backend resides in
       /opt/local/etc/sane.d/coolscan.conf.

       Its content is a list of device names that correspond to Nikon Coolscan
       scanners. Empty lines and lines starting with a hash mark (#) are
       ignored. A sample configuration file is shown below:

        #scsi Vendor Model Type
        scsi Nikon * Scanner
        /dev/scanner

       The special device name must be a generic SCSI device or a symlink to
       such a device.  To find out to which device your scanner is assigned and
       how you can set the permissions of that device, have a look at
       sane-scsi(5).



SCSI ADAPTER TIPS

       Some SCSI-adapters and low-level SCSI drivers do not work correctly with
       this backend and the Coolscan scanners. These systems hang when the
       autofocus command is send to the Scanner.  To see a list of which
       card/driver combinations work or don't work have a look at:
       http://andreas.rick.free.fr/sane/autofocus.html.



FILES

       The backend configuration file:
              /opt/local/etc/sane.d/coolscan.conf

       The static library implementing this backend:
              /opt/local/lib/sane/libsane-coolscan.a

       The shared library implementing this backend:
              /opt/local/lib/sane/libsane-coolscan.so (present on systems that
              support dynamic loading)



ENVIRONMENT

       SANE_DEBUG_COOLSCAN
              If the library was compiled with debug support enabled, this
              environment variable controls the debug level for this backend.
              E.g., a value of 128 requests all debug output to be printed.
              Smaller levels reduce verbosity.

              Examples:

              On bash:
              export SANE_DEBUG_COOLSCAN=8

              On csh:
              setenv SANE_DEBUG_COOLSCAN 8



BUGS

       The autofocus command does not work with some SCSI card/driver
       combinations.

       The gamma table is not implemented for the LS1000 yet.

       The dust-removal is not working yet.



SEE ALSO

       sane(7), sane-scsi(5)


       http://andreas.rick.free.fr/sane/
              The homepage of this backend.

       http://www.sema.be/coolscan/
              The original version of the coolscan backend by Didier.



THANKS TO

       Didier Carlier - For writing the original Coolscan backend (without it I
       would not have started this).

       Oliver Rauch - For adapting xsane so quickly to the infrared stuff.

       All the other people working on SANE.



AUTHOR

       Andreas Rick



EMAIL-CONTACT

       andreas.rick@free.fr