NAME

       sane-epson2 - SANE backend for EPSON scanners


DESCRIPTION

       The sane-epson2 library implements a SANE (Scanner Access Now Easy)
       backend that provides access to Epson flatbed scanners.  This library
       supports a similar set of scanners as the sane-epson driver but was
       developed to support a wider range of connections to the scanner; include
       network access.

       Because sane-epson and sane-epson2 drivers support many of the same
       devices, if one driver gives you problems you may try disabling it to try
       the other.  This can be done by removing the driver name from the
       dll.conf or perhaps by commenting out the options in epson.conf or
       epson2.conf.

       At present, the following scanners are known to work with this backend:

              Model:                       Connection Type
              ---------------------------  -------------------
              ActionScanner II             SCSI, parallel
              AcuLaser CX11 Series         USB, Network
              AcuLaser CX21 Series         USB, Network
              CX-3200                      USB
              CX-3600                      USB
              CX-3650                      USB
              CX-4050                      USB
              CX-4600                      USB
              CX-4800                      USB
              CX-5000                      USB
              CX-5200                      USB
              CX-5400                      USB
              CX-6300                      USB
              CX-6400                      USB
              CX-6500                      USB
              CX-6600                      USB
              DX-3800                      USB
              DX-5000                      USB
              DX-5050                      USB
              DX-6000                      USB
              DX-7400                      USB
              ES-300C                      SCSI, parallel
              ES-300GS                     SCSI
              ES-600C                      parallel
              ES-1200C                     parallel
              Expression 636               SCSI
              Expression 800               SCSI
              Expression 1600              USB, SCSI, IEEE-1394
              Expression 1680              USB, SCSI, IEEE-1394
              FilmScan 200                 SCSI
              GT-5000                      SCSI, parallel
              GT-5500                      SCSI
              GT-6000                      parallel
              GT-6500                      parallel
              GT-7000                      SCSI
              GT-8000                      SCSI
              GT-8500                      SCSI
              Perfection 610               USB
              Perfection 636S              SCSI
              Perfection 636U              USB
              Perfection 640               USB
              Perfection 1200S             SCSI
              Perfection 1200U             USB
              Perfection 1240              USB, SCSI
              Perfection 1640              USB, SCSI
              Perfection 1650              USB
              Perfection 1660              USB
              Perfection 2400              USB
              Perfection 2450              USB, IEEE-1394
              Perfection 3200              USB
              Perfection 4870              USB
              Perfection 4990              USB
              RX-425                       USB
              RX-500                       USB
              RX-600                       USB
              RX-700                       USB
              V700                         USB, IEEE-1394
              V750                         USB, IEEE-1394
              and many more. The official list is on the Sane web site.

       For other scanners the software  may or may not work.  Please send mail
       to the sane-backend mailing list to report success with scanners not on
       the list or problems with scanners that are listed.


OPTIONS

       The options the backend supports can either be selected through command
       line options to programs like scanimage(1) or through GUI elements in
       programs like xscanimage(1) or xsane(1).

       Valid command line options and their syntax can be listed by using

              scanimage --help -d epson2

       Not all devices support all options.

       Scan Mode
              The --mode switch selects the basic mode of operation of the
              scanner. Valid choices are Binary, Gray and Color.  The Binary
              mode is black and white only, Gray will produce 256 levels of gray
              or more depending on the scanner and Color means 24 bit color mode
              or more depending on the scanner.  Some scanners will internally
              use 36 bit color, their external interface however may only
              support 24 bits.

              The --depth option selects the bit depth the scanner is using.
              This option is only available for scanners that support more than
              one bit depth. Older scanners will always transfer the image in
              8bit mode. Newer scanners allow one to select either 8 bits, 12 or
              14 bits per color channel. For a color scan this means an
              effective color depth of 36 or 42 bits over all three channels.
              The valid choices depend on the scanner model.

              The --halftoning switch selects the mode that is used in Binary
              mode. Valid options are "None", "Halftone A (Hard Tone)",
              "Halftone B (Soft Tone)", "Halftone C (Net Screen)", "Dither A
              (4x4 Bayer)", "Dither B (4x4 Spiral)", "Dither C (4x4 Net
              Screen)", "Dither D (8x4 Net Screen)", "Text Enhanced Technology",
              "Download pattern A", and "Download pattern B".

              The --dropout switch selects the so called dropout color. Valid
              options are None, Red, Green and Blue. The default is None. The
              dropout color is used for monochrome scanning and selects the
              color that is not scanned. This can be used to e.g. scan an
              original with a colored background.

              The --brightness switch controls the brightness of the scan. Valid
              options are integer values from -3 to 3. The default is 0. The
              larger the brightness value, the brighter the image gets. If a
              user defined table for the gamma correction is selected, the
              brightness parameter is not available.

              The --sharpness switch sets the sharpness of the image data. Valid
              options are integer values from -2 to 2, with -2 meaning
              "Defocus", -1 "Defocus slightly", 0 "Normal", 1 "Sharpen slightly"
              and 2 "Sharpen".

              The --gamma-correction switch controls the scanner's internal
              gamma correction. Valid options are "Default", "User defined",
              "High density printing" "Low density printing" and "High contrast
              printing".

              The --color-correction switch controls the scanner's internal
              color correction function. Valid options are "No Correction",
              "Impact-dot printers", "Thermal printers", "Ink-jet printers" and
              "CRT monitors". The default is "CRT monitors".

              The --resolution switch selects the resolution for a scan. Some
              EPSON scanners will scan in any resolution between the lowest and
              highest possible value. The list reported by the scanner can be
              displayed using the "--help -d epson" parameters to scanimage(1).

              The --threshold switch selects the minimum brightness to get a
              white point.

              The --mirror option controls the way the image is scanned. By
              reading the image data from right to left the image is mirrored.
              Valid options are "yes" and "no". The default is "no".

              The --auto-area-segmentation switch activates the automatic area
              segmentation for monochrome scans. The scanner will try to
              determine which areas are text and which contain images. The image
              areas will be halftoned, and the text will be improved. Valid
              options are "yes" and "no". The default is "yes".

              The --red-gamma-table parameter can be used to download a user
              defined gamma table for the red channel. The valid options are the
              same as for --gamma-table.

              The --green-gamma-table parameter can be used to download a user
              defined gamma table for the green channel. The valid options are
              the same as for --gamma-table.

              The --blue-gamma-table parameter can be used to download a user
              defined gamma table for the blue channel. The valid options are
              the same as for --gamma-table.

              The --wait-for-button parameter can be used to wait until the
              button on the scanner is pressed to actually start the scan
              process.

              The color correction coefficients --cct-1 --cct-2 --cct-3 ...
              --cct-9 will install color correction coefficients for the user
              defined color correction. Values are specified as integers in the
              range -127..127.

              The --preview option requests a preview scan. The frontend
              software automatically selects a low resolution. Valid options are
              "yes" and "no". The default is "no".

              The geometry options -l -t -x -y control the scan area: -l sets
              the top left x coordinate, -t the top left y coordinate, -x
              selects the width and -y the height of the scan area. All
              parameters are specified in millimeters.

              The --source option selects the scan source. Valid options depend
              on the installed options. The default is "Flatbed".

              The --auto-eject option will eject a page after scanning from the
              document feeder.

              The --film-type option will select the film type for scans with
              the transparency unit. This option is only activated if the TPU is
              selected as scan source. Valid options are "Negative Film" and
              "Positive Film".

              The --focus-position option selects the focus position for all
              scans. Valid options are "Focus 2.5mm above glass" and "Focus on
              glass". The focus on the 2.5mm point above the glass is necessary
              for scans with the transparency unit, so that the scanner can
              focus on the film if one of the film holders is used.  This option
              is only functional for selected scanners, all other scanners will
              ignore this option.

              The --bay option selects which bay to scan

              The --eject option ejects the sheet in the ADF.

              The --adf-mode option select the ADF mode (simplex/duplex).



CONFIGURATION FILE

       The configuration file /opt/local/etc/sane.d/epson2.conf specifies the
       device(s) that the backend will use. Possible connection types are:

       SCSI   This is the default, and if nothing else is specified the backend
              software will open a given path as SCSI device. More information
              about valid syntax for SCSI devices can be found in sane-scsi(5).
              Usually SCSI scanners are configured with a line "scsi EPSON" in
              this file. In some cases it may be necessary to only use the
              string "scsi" (e.g. for the GT-6500).

       PIO - Parallel Interface
              The parallel interface can be configured in two ways: An integer
              value starting at the beginning of a line will be interpreted as
              the IO address of the parallel port. To make it clearer that a
              configured IO address is a parallel port the port address can be
              preceded by the string "PIO". The PIO connection does not use a
              special device file in the /dev directory. The IO address can be
              specified in hex mode (prefixed with "0x").

       USB    For USB scanners not automatically detect, their VENDOR and
              PRODUCT ID can be specified manually in the config file.  More
              information about valid syntax for USB devices can be found in
              sane-usb(5).

       Network
              Network scanners can be auto-discovered if autodiscovery is
              specified after net keyword.  An IP address to connect to can also
              be used.


FILES

       /opt/local/lib/sane/libsane-epson2.a
              The static library implementing this backend.

       /opt/local/lib/sane/libsane-epson2.so
              The shared library implementing this backend (present on systems
              that support dynamic loading).


ENVIRONMENT

       SANE_DEBUG_EPSON2
              If the library was compiled with debug support enabled, this
              environment variable controls the debug level for this backend.
              E.g., a value of 128 requests all debug output to be printed.
              Smaller levels reduce verbosity.

       SANE_DEBUG_EPSON2_SCSI
              If the library was compiled with debug support enabled, this
              environment variable controls the SCSI related debug level for
              this backend.  Only a value of 2 is supported.

       SANE_DEBUG_EPSON2_NET
              If the library was compiled with debug support enabled, this
              environment variable controls the network related debug level for
              this backend.  E.g., a value of 128 requests all debug output to
              be printed.  Smaller levels reduce verbosity.

       SANE_EPSON2_CMD_LVL
              This allows one to override the function or command level that the
              backend uses to communicate with the scanner. The function level a
              scanner supports is determined during the initialization of the
              device. If the backend does not recognize the function level
              reported by the scanner it will default to function level B3.
              Valid function levels are A1, A2, B1, B2, B3, B4, B5, B6, B7, B8,
              D1 and F5. Use this feature only if you know what you are doing!



SEE ALSO

       sane-scsi(5), sane-usb(5), scanimage(1), xscanimage(1), xsane(1)



BUGS

       None :-) At least none are currently known.



UNSUPPORTED DEVICES

       The backend may be used with Epson scanners that are not yet listed under
       the list of supported devices. A scanner that is not recognized may
       default to the function level B3, which means that not all functions that
       the scanner may be capable of are accessible.

       If the scanner is not even recognized as an Epson scanner this is
       probably because the device name reported by the scanner is not in the
       correct format. Please send this information to the backend maintainer
       (email address is in the AUTHOR section of this man page or in the
       AUTHORS file of the SANE distribution).



AUTHOR

       The package is written by Alessandro Zummo and is based on previous work
       done by Karl Hienz Kremer in the epson package as well as based on work
       by Christian Bucher and Kazuhiro Sasayama.



                                   22 Jan 2009                    sane-epson2(5)