sane-lexmark(5)           SANE Scanner Access Now Easy           sane-lexmark(5)




NAME

       sane-lexmark - SANE backend for Lexmark X1100/X1200 Series scanners


DESCRIPTION

       The sane-lexmark library implements a SANE (Scanner Access Now Easy)
       backend that provides access to the scanner part of Lexmark X1100/X1200
       AIOs. This backend should be considered beta-quality software!

       The scanners that should work with this backend are:

                 Vendor Model           status
              ----------------------  -----------
                Lexmark X74             good
                Lexmark X1110           untested
                Lexmark X1140           untested
                Lexmark X1150           good
                Lexmark X1170           good
                Lexmark X1180           good
                Lexmark X1185           complete
                Lexmark X12xx           good in USB1.1,
                                        not fully tested in USB2.0
                Dell    A920            good

       The options the backend supports can either be selected through command
       line options to programs like scanimage(1) or through GUI elements in
       xscanimage(1) or xsane(1).

       If you notice any strange behavior, please report to the backend
       maintainer or to the SANE mailing list.

       Valid command line options and their syntax can be listed by using

              scanimage --help -d lexmark:usb:<usb port>


       Scan Mode Options


       --mode selects the basic mode of operation of the scanner. Valid choices
              are Color, Gray and Lineart.  The default mode is Color.  The
              Lineart mode is black and white only (1 bit).  Gray mode will
              produce 256 levels of gray (8 bits).  Color mode allows for over
              16 million different colors produced from 24 bits of color
              information.


       --resolution
              selects the resolution for a scan. The horizontal and vertical
              resolutions are set by the value of this option. The scanner is
              capable of the following resolutions for the specified option
              value:

                Value   Hor. Resolution  Vert. Resolution
                -----   ---------------  -------------------
                75      75dpi            75dpi
                150     150dpi           150dpi
                300     300dpi           300dpi
                600     600dpi           600dpi
                1200    600dpi           1200dpi  (only for X11xx models with 'B2' sensor)


       --preview
              requests a preview scan. The resolution used for that scan is 75
              dpi and the scan area and the scan mode are as specified through
              their options, or the default if not specified. The default value
              for preview mode is "no".


       --threshold
              selects the  minimum-brightness to get a white point. The
              threshold is only used with Lineart mode scans.  It is specified
              as a percentage in the range 0..100% (in steps of 1).  The default
              value of the threshold option is 50.




CONFIGURATION FILE

       The configuration file /opt/local/etc/sane.d/lexmark.conf contains only
       the usb device id (eg usb 0x043d 0x007c).




FILES

       /opt/local/lib/sane/libsane-lexmark.a
              The static library implementing this backend.

       /opt/local/lib/sane/libsane-lexmark.so
              The shared library implementing this backend (present on systems
              that support dynamic loading).




ENVIRONMENT

       SANE_DEBUG_LEXMARK
              If the library was compiled with debug support enabled, this
              environment variable controls the debug level for this backend.
              E.g., a value of 255 requests all debug output to be printed.
              Smaller levels reduce verbosity.

       SANE_DEBUG_LEXMARK_LOW
              Provides debug output for low level Lexmark functions.



LIMITATIONS

       The windows TWAIN driver has many more options than this SANE backend.
       However they are only software adjustments. This backend only implements
       what the scanner can support. For instance, shading correction (vertical
       stripes due to sensor variation across its width) is done in software.
       Head park position is also detected by software.  The data compression
       isn't supported for the X1200 series on USB 1.1, leading to slow scans.



BUGS

       No bugs currently known.





SEE ALSO

       sane-scsi(5), scanimage(1), xscanimage(1), xsane(1), sane(7)




AUTHOR

       The backend was originally written by Fred Odendaal.
              http://ca.geocities.com/freshshelf@rogers.com/

       The new version is currently developed by Stephane Voltz.
              http://stef.dev.free.fr/sane/lexmark

       X74 support was written by Torsten Houwaart
              <ToHo@gmx.de>



CREDITS

       Many thanks go to:
              Julien Furgerot who lent me a Dell A920.  Robert Price, Dani Ele
              and Dalai Felinto for the time they spent recording USB activity
              and testing the experimental version.



                                   12 Jul 2008                   sane-lexmark(5)