manpagez: man pages & more
man sane-microtek2(5)
Home | html | info | man
sane-microtek2(5)         SANE Scanner Access Now Easy         sane-microtek2(5)




NAME

       sane-microtek2 - SANE backend for Microtek scanners with SCSI-2 command
       set


DESCRIPTION

       The sane-microtek2 library implements a SANE (Scanner Access Now Easy)
       backend that provides access to Microtek scanners with a SCSI-2 command
       set.  This backend can be considered alpha to beta. Some scanner models
       are reported to work well, others not. New development versions of this
       backend can be obtained from http://karstenfestag.gmxhome.de.

       There exists a different backend for Microtek scanners with SCSI-1
       command set.  Refer to sane-microtek(5) for details.

       And there is work in progress for the ScanMaker 3600.  See
       http://sourceforge.net/projects/sm3600.

       At present, the following scanners are known positively to work with this
       backend:

       Vendor     Product id        Remark
       --------------------------------------------------------------------
       Microtek   E3+               Parport and SCSI
       Microtek   X6                SCSI
       Microtek   X6EL              SCSI
       Microtek   X6USB             USB
       Microtek   ScanMaker V300    Parport and SCSI
       Microtek   ScanMaker V310    Parport and SCSI
       Microtek   ScanMaker V600    Parport and SCSI
       Microtek   ScanMaker 330     SCSI
       Microtek   ScanMaker 630     SCSI
       Microtek   ScanMaker 636     SCSI
       Microtek   ScanMaker 9600XL  SCSI; only flatbed mode?
       Microtek   Phantom 330CX     Parport
       Microtek   SlimScan C3       Parport
       Microtek   SlimScan C6       USB
       Microtek   Phantom 636       SCSI
       Microtek   Phantom 636CX     Parport
       Microtek   V6USL             SCSI and USB
       Microtek   V6UPL             USB; not stable
       Microtek   X12USL            SCSI; only 8bit color, work in progress
       Vobis      HighScan          SCSI (E3+ based models)
       Scanport   SQ300             Parport?
       Scanport   SQ4836            SCSI
       Scanpaq    SQ2030            Parport

       Additional information can be found at http://www.sane-project.org/.

       If you own a Microtek scanner other than the ones listed above, it may or
       may not work with SANE! Because equal scanners are sold under different
       names in different countries your model may be equivalent to one of the
       above.

       The parport scanners work with the ppscsi + onscsi kernel modules. See
       http://cyberelk.net/tim/parport/ppscsi.html and
       http://penguin-breeder.org/kernel/download/.


       The USB scanners work with the microtek kernel module. You may have to
       add the vendor and model codes to microtek.c if they aren't yet listed
       there.

       Both parport and USB scanners need the generic SCSI support, so check if
       you have loaded the scsi_mod and sg modules!

       If you try your scanner for the first time keep an eye on it. If it gets
       commands that it doesn't understand the scanhead may go beyond the scan
       area.  The scanner then makes strange noises. In this case immediately
       switch off the scanner or disconnect its power cable to prevent damages!

       If your scanner is a different one than the models mentioned above and it
       is working please tell the author about it. It would be nice if you add a
       logfile to this information (creation of the logfile: see below).

       If your scanner is not working properly you also should create a logfile
       and send it to the author. He will use the information to improve the
       backend and possibly make your scanner work.

       How to create the logfile?

       - put the line
              "option dump 2" into your microtek2.conf file or change the
              existing "option dump" to "2"

       - in a terminal (bash) type
              "export SANE_DEBUG_MICROTEK2=30" and then
              "scanimage -l0 -t0 -x100 -y20 2>scan.log >sout.pnm"
              You get two files: scan.log contains the logfile and sout.pnm the
              scanned image (if there was scanned something). Zip them before
              sending.



FRONTEND OPTIONS

       This backend dynamically enables the options for the frontend, that are
       supported by the scanner in dependence of the scanning-mode and other
       options.  Not supported options are disabled.

       The following options are supported by the sane-microtek2 driver:

       Color, grayscale, halftone and lineart scans.

       Highlight, midtone, shadow, contrast, brightness, exposure time control,
       gamma correction, threshold (dependent of the scan mode and the scanner
       capabilities)

       Transparency media adapter, automatic document feeder

       Additional options can be enabled or disabled in the microtek2.conf file.
       See the configuration section of this manpage.



DEVICE NAMES

       This backend expects device names of the form:

              special

       Where special is the UNIX path-name for the special device that
       corresponds to the scanner.  The special device name must be a generic
       SCSI device or a symlink to such a device.  Under Linux, such a device
       name could be /dev/sga or /dev/sge for example.


CONFIGURATION

       The configuration file for this backend resides in
       /opt/local/etc/sane.d/microtek2.conf.

       Its contents is a list of device names that correspond to Microtek
       scanners with SCSI-2 interface. Empty lines and lines starting with a
       hash mark (#) are ignored.

       The configuration file may also contain options. Global options that are
       valid for all devices are placed above the device names. Device-specific
       options are placed under the device name. Note that, except for option
       dump <n> and option strip-height <n>, the entry in the microtek2.conf
       file only enables the corresponding option for being showed in the
       frontend. There, in the frontend, you can switch the options on and off.
       Currently the following options are supported:

              option dump <n>
              option strip-height <n>
              option no-backtrack-option <on/off>
              option lightlid-35 <on/off>
              option toggle-lamp <on/off>
              option lineart-autoadjust <on/off>
              option backend-calibration <on/off>
              option colorbalance-adjust <on/off>

       option dump <n> enables printing of additional information about the SCSI
       commands that are sent to the scanner to stderr. This option is primarily
       useful for debugging purpose. This option has to be a global option and
       is best placed at the top of the microtek2.conf file.

       If n=1 the contents of the command blocks and the results for the INQUIRY
       and READ SCANNER ATTRIBUTES command are printed to stderr.

       If n=2 the contents of the command blocks for all other SCSI commands are
       printed to stderr, too. If n=3 the contents of the gamma table is
       printed, too. If n=4 all scan data is additionally printed to stderr.

       The default is n=1.

       option strip-height <n> , where <n> is a floating point number, limits
       the amount of data that is read from the scanner with one read command.
       The unit is inch and <n> defaults to 1.0, if this option is not set in
       the configuration file. If less than <n> inch of data fit into the SCSI
       buffer, then the smaller value is used and this option has no effect.

       If your system has a big SCSI buffer and you want to make use of the
       whole buffer, increase the value for <n>. For example, if <n> is set to
       14.0, no restrictions apply for scanners with a letter, legal or A4 sized
       scan area.

       The following options enable or disable additional frontend options. If
       an option is set to <on> an appropriate option will appear in the
       frontend.

       option no-backtrack-option <on/off> prevents the scanner head from moving
       backwards between the read commands.  This speeds up scanning. Try it.

       option lightlid-35 <on/off> If you use the LightLid-35 transparency
       adapter you get an advanced option which switches off the flatbed lamp
       during the scan.

       option toggle-lamp <on/off> You get a button in the frontend where you
       can switch on and off the flatbed lamp.

       option lineart-autoadjust <on/off> You can tell the backend to try to
       determine a good value for the lineart threshold.

       option backend-calibration <on/off> Some scanners (e.g. Phantom 330CX and
       636CX) need to have calibrated the data by the backend. Try this option
       if you see vertical stripes in your pictures.

       option colorbalance-adjust <on/off> Some scanners (e.g. Phantom 330CX and
       636CX) need to have corrected the color balance. If this option is
       enabled you get advanced options where you can balance the colors. And
       you will have a button to use the values that the firmware of the scanner
       provides.

       A sample configuration file is shown below:

              option dump 1
              option strip-height 1.0
              /dev/scanner
              option no-backtrack-option on
              # this is a comment
              /dev/sge
              option lightlid-35 on

       This backend also supports the new configuration file format which makes
       it easier to detect scanners under Linux. If you have only one scanner it
       would be best to use the following configuration file for this backend:

              option dump 1
              option strip-height 14.0
              option no-backtrack-option on
              option backend-calibration on
              option lightlid-35 on
              option toggle-lamp on
              option lineart-autoadjust on
              option colorbalance-adjust off
              scsi * * Scanner

       In this case all SCSI-Scanners should be detected automatically because
       of the

       scsi * * Scanner

       line.



FILES

       /opt/local/etc/sane.d/microtek2.conf
              The backend configuration file.

       /opt/local/lib/sane/libsane-microtek2.a
              The static library implementing this backend.

       /opt/local/lib/sane/libsane-microtek2.so
              The shared library implementing this backend (present on systems
              that support dynamic loading).


ENVIRONMENT

       SANE_DEBUG_MICROTEK2
              If the library was compiled with debug support enabled, this
              environment variable controls the debug level for this backend.
              E.g., a value of 255 requests all debug output to be printed.
              Smaller levels reduce verbosity. To see error messages on stderr
              set SANE_DEBUG_MICROTEK2 to 1 (Remark: The whole debugging levels
              should be better revised).
              E.g. just say:
              export SANE_DEBUG_MICROTEK2=128



SEE ALSO

       sane-scsi(5), sane(7)



AUTHORS

       Bernd Schroeder (not active anymore)
       Karsten Festag <karsten.festag@gmx.de>.



                                   13 Jul 2008                 sane-microtek2(5)

sane-backends 1.2.1 - Generated Sat Feb 25 08:06:01 CST 2023